BrandIBP
ModelHL 168 V 92
Product typeAutomatic wrist blood pressure monitor
Measurement methodOscillometric
Pressure measurement range0 to 300 mmHg
Pulse measurement range40 to 200 beats/min
Pressure accuracy± 3 mmHg
Pulse accuracy± 5 %
InflationAutomatic by air pump
DisplayLCD screen
Memory92 measurements with date and time
Power supply2 AAA alkaline batteries 1.5 V
Dimensions (L x W x H)70 x 72 x 29 mm
Weight (with batteries)Approximately 140 g
Compatible wrist circumference135 to 195 mm
Operating temperature+10 °C to +40 °C, 30–85 % RH
Storage temperature-20 °C to +50 °C, 10–95 % RH
Included accessoriesCarrying case, user manual, 2 AAA batteries
MaintenanceClean the case with a damp cloth and mild detergent; wipe cuff with a dry cloth
SafetyDo not use on an injured wrist; consult a doctor in case of arrhythmia
Warranty24 months (excluding wear and misuse)
After-sales serviceIBP GmbH, Am Weimarer Berg 6, D-99510 Apolda, Germany

Frequently Asked Questions - HL 168 V 92 IBP

How to correctly put on the wrist blood pressure monitor?
Wrap the cuff around the bare wrist, the display should be on the palm side. Tighten comfortably without pulling too hard. The wrist should be at heart level.
Why do measurements vary between morning and evening?
Blood pressure naturally varies: it is usually lower in the morning and increases in the afternoon and evening. It is normal to observe variations.
How many measurements can I store in memory?
The device can store up to 92 measurements with date and time. When the memory is full, the oldest ones are automatically erased.
How to view recorded measurements?
Press the Recall area to display the last measurement. Press again to scroll through previous measurements. The data is displayed for 60 seconds.
How to delete all memory data?
Remove the batteries, then put in two new ones. Check that the memory is empty by pressing Recall: no data should appear.
Which batteries to use and how long do they last?
Use 2 AAA 1.5 V alkaline batteries. They allow approximately 250 measurements.
What to do if the screen displays 'Error'?
Check that the cuff is correctly attached to the wrist, that you are not moving or talking during the measurement. Press the screen again to restart the measurement.
Can I use this device if I have a pacemaker?
Consult your doctor. The device is intended for home use but interference is possible. As a precaution, seek medical advice.
How to clean the blood pressure monitor?
Clean the case with a soft cloth dampened with water or mild detergent, then wipe dry with a dry cloth. For the cuff, use a dry cloth. Do not use gasoline or solvents.
What to do if the cuff inflates without stopping?
Immediately open the cuff to release the air. If the problem persists, contact after-sales service.

User questions about HL 168 V 92 IBP

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Blood pressure monitor in PDF format for free! Find your manual HL 168 V 92 - IBP and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HL 168 V 92 by IBP.

USER MANUAL HL 168 V 92 IBP

1 introduction 2
2 preliminary remarks 3
3 about blood pressure what is blood pressure 4 why is it useful to measure blood pressure at home? 4

A WHO blood pressure classifications 5
B variations in blood pressure 5 important information before use of the unit 6-7

4 the unit - accessories identification of the unit. 8
5 description of display symbols 9
6 changing batteries 10
7 attaching pressure cuff A wrap the pressure cuff around the wrist. 11 B fasten the pressure cuff snugly. 11
8 correct measurement position measurement while sitting down 12
9 description of display marks 13

10 how to measure A inserting batteries in position 14 B setting Date and Time. 14 C steps to take blood pressure measurement. 14-15 D storing, recalling and erasing measurement data. 15-16 E to change batteries 16

11 general maintenance 16 safe-keeping 17 to prevent malfunction.. 17 warning 17
12 specifications 18

1 introduction

dear customer,

we are glad that you have decided for this blood pressure monitor. The product you have bought is state of the art, of highest quality and has many advanced features. Because the device has a memory, which can store 92 values, you can easily track changes and notify your doctor in good time if problems are detected. The unit is determined for household use and should be used by adult persons only.

important notes !

Please read this Instruction Manual carefully to know your blood pressure monitor. Then the monitor will give you many years of smooth service and supply measuring data of high accuracy. Only your physician can interpret your blood pressure values. If you suffer from cardiac arrhythmia, always discuss the blood pressure values with your doctor. If you have questions about blood pressure for which you do not find an answer in this booklet, also consult your doctor.

The right to technical modifications is reserved.

  • This Blood Pressure Monitor bears the CE (conformity) label „CE 0344" for notinvasive Blood Pressure Monitors to show that it conforms with the EU Council Directive (EN 1060-1 / EN 1060-3) for notinvasive Blood Pressure Monitors. It also confirms with the EU Council Directive "93/42/EEC of 14th June 1993 on Medical Products" and with "89/336/EEC".
  • ibp hereby confirms that the product delivered together with this Instruction Manual complies with this Directive. The appropriate conformity declaration is available with ibp.
  • To ensure accurate measurements, the Blood Pressure Monitor must receive a technical check-up every 2 years. Inspection is also required when the blood pressure data supplied by the monitor are obviously off-range. If you have questions regarding this inspection, please write to the service address (on the guarantee certificate).
  • The CE mark of the device corresponds to EC directive 93/42/EEC. The blood pressure measuring device corresponds to European regulations EN 1060 part 1 and EN 1060 part 3.
  • Measures human beings Systolic, Diastolic blood pressure and heart rate using the oscillometric method. All values can be read out in one LCD Display. Measurement position is on adult wrist only.

3 about blood pressure

what is blood pressure?

Blood pressure is a measurement of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, the lowest is the diastolic blood pressure. Both pressure readings, the systolic and the diastolic are necessary to enable a physician to evaluate the status of a patient's blood pressure. Many factors such as physical activity, anxiety or the time of day, can influence your blood pressure. Blood pressure is typically low in the morning and increases from the afternoon to the evening. It is lower in the summer and higher in the winter.

why is it useful to measure blood pressure at home?

Having one's blood pressure measured by a doctor in a hospital or a clinic, and a group health checks, tend to stimulate nervousness in the subject and may even create high blood pressure. Also varies blood pressure in accordance with a variety of conditions and so judgment is not possible on the basis of a single measurement.

The blood pressure measured first thing in the morning after getting up, before taking any food and with the subject still, is known as the fundamental blood pressure. In practice it is rather difficult to record the fundamental blood pressure, but to come as near as possible to measuring the blood pressure in an environment that is close to this, is why it is useful to take the measurement at home.

A WHO blood pressure classifications

Standards for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart.

IBP HL 168 V 92 - A WHO blood pressure classifications - 1

B variations in blood pressure

Individual blood pressures vary greatly both on a daily and a seasonal basis. These variations are even more pronounced in hypertense patients. Normally the blood pressure rises while at work and is at its lowest during sleeping period.

(hypertense: means a person who has high blood pressure symptom.)

IBP HL 168 V 92 - B variations in blood pressure - 1

The graph below illustrated the variations in blood pressure over a whole day with measurement taken every five minutes.

The thick line represents sleep. The rise in blood pressure at 4 PM (A in the graph) and 12 PM (B in the graph) correspond to an attack of pain.

3 about blood pressure

important information before use of the unit

  • Blood pressure measurements should be interpreted by a physician or trained health professional who is familiar with your medical history. By using the unit regularly and recording the results for your physician to interpret, you keep your physician informed of the continuing trends in your blood pressure.
  • Wind the cuff snugly around your wrist and the cuff must be at the same level as your heart.
  • Do not vibrate the unit during measurement, or the proper measurement will not be achieved.
  • Perform measurement quietly in a relaxed position.
  • Do not wind the cuff over jacket or sweater sleeve, or measurement cannot be done.
  • Keep in mind, that blood pressure naturally varies from time to time through out the day and also is affected by lots of different factors such as smoking, alcohol consumption, medicamentation and physical activity.
  • People with a condition that causes circulatory problems (diabetes, kidney disease, arteriosclerosis or poor peripheral circulation) may get lower readings with this monitor that with a blood pressure monitor that is used on the upper arm. Please consult your physician to determine if your wrist blood pressure accurately reflects your actual blood pressure.

about blood pressure 3

  • Blood pressure measurement determine with the unit are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method.

4 the unit - accessories

IBP HL 168 V 92 - the unit - accessories - 1
identification of the unit

description of display symbols 5

IBP HL 168 V 92 - description of display symbols 5 - 1

6 changing batteries

Remove the protective foil/film from the display. Remove the battery cover at the left side of the unit and insert batteries into the battery compartment as shown, taking extreme care that the polarities + and - are observed.

IBP HL 168 V 92 - changing batteries - 1

IBP HL 168 V 92 - changing batteries - 2

IBP HL 168 V 92 - changing batteries - 3

Important: Your might encounter difficulties to take the batteries out. If so, use a hard and tiny object such as a small screwdriver or others for help.

Discharged batteries should not be discarded with household refuse.

Dispose of discharged batteries at a recycling point.

Remove the batteries from the appliance if it is not to be used for a long period.

Safety advice:

  • Keep away from children!

  • Do not short-circuit!

  • Not rechargeable!

  • Do not throw into fire!

attaching pressure cuff 7

A wrap the pressure cuff around the wrist.

  1. The display of the unit should be placed on the palm side of the wrist.
  2. The wrist should be bare.

IBP HL 168 V 92 - A wrap the pressure cuff around the wrist. - 1

IBP HL 168 V 92 - A wrap the pressure cuff around the wrist. - 2

B fasten the pressure cuff snugly.

  1. Do not pull on the pressure cuff.
  2. Do not make the pressure cuff too tight.

IBP HL 168 V 92 - B fasten the pressure cuff snugly. - 1

IBP HL 168 V 92 - B fasten the pressure cuff snugly. - 2

8 correct measurement position

It is extremely important for the measured values, that the cuff is at the same height of the heart. Higher or deeper position will give deviations from the true value.

measurement while sitting down:

  1. Place your elbow on a table or other object (such as our carry case).
  2. Use the armrest to position the arm so that the pressure cuff is at the same height as the heart.
  3. Relax your hand with the palm facing up.

IBP HL 168 V 92 - measurement while sitting down: - 1

description of display marks 9

Display markCondition/CauseCorrective action
Mark appears in the measurement condition and flashes when pulse is detected.Measurement in progress remain quiet. Don’t move.
Replace batteriesAppears when the battery voltage is excessively low or the positions of batteries are incorrect.Replace all two batteries by new ones. Insert the batteries at correct positions beware of the +/- directions.
Measuring errorAppears when the accurate blood pressure could not be obtained accurately.Press Display area again and re-measure. Or check cuff if wrapped at the wrist or according to instructions. Check palm if exerting effort. Check if talking or moving during measurement. Check if posture is incorrect.
Measuring blood Pressure symbolAppears all the time till the measurement being completed.

10 how to measure

A inserting batteries in position:

a) Open battery cover.
b) Refer to the picture in positioning batteries.
c) All LCD segments appear on the display in a short time.
d) Display 1 month, 1 date, 12 hours, 0 minute.

B setting Date and Time:

You may use the pointer or finger or pen whatever, to set Date, time.

a) Press Mode icon ("month" starts flashing). Press Set icon to set the correct month.
b) Press Mode icon again ("date" starts flashing). Press Set icon to set the correct date.
c) Press Mode icon again ("hour" starts flashing). Press Set icon to set the correct hour in 12-hour format.
d) Press Mode icon again ("minute" starts flashing). Press Set icon to set the correct minute.
e) Press Mode icon again to switch to normal time (month, date, hour and minute appear on the display). The two flashing dots after the hours indicate that the clock is active.

C steps to take blood pressure measurement:

a) Wrap the cuff around the wrist. (Refer to Wrapping of Wrist cuff as, page 11.)
b) Sit upright on the chair to have correct posture. (Refer to correct Posture in Taking Blood Pressure as, page 12.)

c) Press the central part of whole LCD display. The update time is displayed for 3 seconds. The measuring blood pressure symbol will flash on the display and then the air pressure tends automatically to be on the high level of 195mmHg . The air pressure will automatically increase to the required level for measurement. Do not move or talk in the midst of taking blood pressure measurement.
d) After the air pressure is increased, it will slowly decreased. When the pulse rate is detected, Heart Rate symbol will start flashing.
e) After taking blood pressure measurement, the Systolic rate, the Diastolic rate and the Pulse Rate will be shown on the display for 1 minute and will then be removed automatically.

D storing, recalling and erasing measurement data:

a) Storing data:

After each blood pressure measurement, the Systolic rate, diastolic rate, heart pulse rate and the time & date of specific day will be automatically stored. The memory holds the latest 92 measurement data. If more than 92 measurements, the memory will automatically clear out the earliest data.

b) Recalling data:

  1. Pressing Recall icon at normal time, the latest recorded set of measurement which are the Systolic rate, Diastolic rate, heart pulse, including the recording time and date, will appear and lasting on the display for 1 minute (60 sec.).

10 how to measure / general

  1. Press Recall icon to read the next line of stored data. The data called up on the display is numbered accordingly. After reading the recalled data as rotatory 92-set of the stored data, press Recall again to switch to normal time.
  2. To discontinue in the midst of reading of the data, press the central part of whole LCD display to power off. The current time then reappears in the display.

c) Erasing data:

  1. Take out the batteries and then refill 2 pcs batteries again.
  2. To discontinue if the data is erased. Press Recall icon, no data should show up on the screen.

E to change batteries:

When " " show up on the display, the battery is weak.

Change the batteries or it will not be possible to take blood pressure measurement.

maintenance:

  • Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece of dry cloth to wipe it dry. Wipe wrist cuff with a dry cloth if it is dirty.
  • Do not use gas or any strong cleansers in cleaning.
  • When the unit is not to be used for a long time, remove the batteries. (Leaking of battery liquid of battery liquid can cause trouble).

safe-keeping:

  • Always keep the unit in the carrying case after its use.
  • Do not put the item directly under the sunlight, in high temperature, or humid and dusty places.
  • Do not store in extremely low (less than -20^ ) or high (more than 60^ ) temperture.

to prevent malfunction:

  • Do not in any way twist the wrist cuff.
  • Do not start the air pressure when the wrist cuff is not wrapped around the wrist.
  • Do not attempt to disassemble or change any parts of the monitor including wrist cuff.
  • Do not drop the product or put it through strong impact.

warning:

The device measures the blood pressure of adults only.
The device is not supposed to be used if your wrist has any wound or injury.
In case the cuff is pumping up and doesn't stop, please open the cuff at once.

12 specifications

Model No.:HL 168 V 92
Method of Measurement:Oscillometric
Range of Measurement:Pressure 0~300mmHg, pulse 40~200 beats/minute
Accuracy Calibration:Pressure +/- 3mmHg, Pulse +/- 5%
Fuzzy Pressure:Automatic Re-inflation pump system
Inflation:Automatic inflation (Air Pump)
Deflation of Pressure:Automatic air release control valve
Exhaust:Automatic exhaust valve
Display:Liquid Crystal Digital Display (LCD)
Sets of Memory:92 set
Unit Dimension:70 x 72 x 29 mm
Unit Weight:Approx. 140g (including batteries)
Cuff Size:Wrist circumference approx. 135 ~ 195mm
Operating Temperature:+10°C to +40°C, 30-85% RH
Storage Temperature:-20°C to +50°C, 10-95% RH
Power Supply:2 x 1,5V alkaline batteries size AAA
Battery Life:Approx. 250 times measurement
Accessories:Carrying case, instruction manual, 2 pcs AAA battery

These specification are subject to change without notice for purpose of improvement.

Service and Warranty

Service Addresses:

England: International Business Products Limited, 6 Newfield Court, West Houghton, Bolton BL5 3 SA England, Phone: +44(0) 19 42 - 8196 95

India: sano health care products Pvt. Ltd., Corporate Office: 28, Landsdown Terrace, 1st Floor Kolkata - 700 026, Phone: +91 33 2465 0383-85

Warranty and Compensation for Damages

Starting with the purchase date (date on proof of purchase or receipt) we will perform repairs free of charge for 24 months, should your device be non-operational due to manufacturing or material defects.

The warranty excludes damage resulting from non-compliance or only partial compliance with these instructions for use.

Further-reaching claims such as compensation for damages are likewise excluded.

Please send your device in question as well as the proof of purchase or receipt and the description of the complaint to our service address. Please also attach the warranty documents if you would like to file a warranty claim.

Waste disposal and care of the environment

At the end of its life cycle, this product must not be disposed of in regular domestic waste, but must be taken to a collection site for recycling electric and electronic devices (disposal of used appliances).

Battery safety information: - Keep away from children!

  • Do not short-circuit!
  • Not rechargeable!
  • Do not incinerate!

chere cliente, cher client,